How Much Attic Venting Do I Need

You can only bring in as much air as you can discharge out of your attic vents.
How much attic venting do i need. Calculate 20 per cent more for 7 12 to 10 12 pitches and 30 per cent more for a pitch that is 11 12 or greater. If the slope of your roof is greater than 6 12 you will need more ventilation to reflect the extra volume of attic space. The federal housing administration recommends 1 square foot of attic ventilation for every 150 square feet of attic space. Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Calculate the total vent area needed. Ideally there should also be plenty of soffit intake space their calculations recommend 336 net square inches of open soffit. You mention exhaust vents shouldn t exceed intake vents in the roof for proper circulation. Venting plays a huge part in how your quietcool whole house fan system works to its full potential.
I need additional exhaust ventilation in my roof with the planned installation of a whole house fan in the attic of my home located in sf bay area. Rafter vents or insulation baffles install in any rafter space to create narrow gaps that direct fresh air from the soffit vents to the peak of the roof. We always recommend at least having 1 sqft of net free area venting for every 750 cfm in your system. However with only two 1 ft x 2 ft gable roof vents i ll need an additional 7 sq ft of exhaust vents.
Ft of attic space for example 20 x 50 to be effective. This will give you the amount of net free venting in square feet required for the fan you select. Do not use mechanical means electric attic fans. According to the home ventilating institute hvi powered attic ventilators need to move a minimum of 700 cubic feet per minute cfm for 1 000 sq.
Determine how much net free venting your fan will require. A 50 x 30 attic would have a total area of 1 500 sq. The answer is rafter venting. Venting a homes attic is a very important best building practices will say 50 at the ridge and 50 at the soffits unobstructed.
Length x width of attic in feet 150 total sq. Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space. Multiply the length of the attic times the width in feet to find the attic area then divide by 150 to find the total square feet of vent space needed. As a certified licensed home inspector it is not correct to say too much ventilation is bad for an attic unless rain moisture is getting in.
Take the total cubic feet per minute of air flow cfm of the fan and divide by 750 2. Of total vent space needed.